[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[bluetooth-dev] attempting service discovery



I hope someone can shed some light on this...

I have an Axis development board, and I am trying to issue an SDP
request to it from an iPAQ running WindowsCE Version 3.0.  It is
using a Socket Communications Bluetooth CompactFlash card.

I can successfully find the development board's bluetooth interface
with the iPAQ, but when I try a service discovery a failure occurs.

I recompiled the bt stack to enable most of the debug output.
Following is what gets printed to the from the kernel after the
service discovery is initiated.

Any help will be greatly appreciated.  Thanks.

Regards,
Steve
_____________________
Stephen Bardsley
RLW Inc.
Malta, NY 

----------- kernel debug output ------------

[1744.570052 <038.215521>] hci_receive_data:  (13):
0x04 0x04 0x0a 0x61 0x18 0x7b 0x03 0xe0 0x00 0x00 0x00 0x00 0x01 
hci_receive_data: hci-13
HCI: hci_receive_data: WAIT_FOR_PACKET_TYPE
HCI: hci_receive_data: WAIT_FOR_EVENT_TYPE
HCI: hci_receive_data: WAIT_FOR_EVENT_LENGTH

[1744.574114 <000.004062>] process_event (10):
0x61 0x18 0x7b 0x03 0xe0 0x00 0x00 0x00 0x00 0x01 
HCI: process_event: CONNECTION_REQUEST
HCI: lp_connect_rsp: Status: 1
BT SYS: lp_connect_rsp: Early m/s switch
HCI: accept_connection_request: bd_addr 61 18 7b 3 e0 0
HCI: insert_cmd
HCI: send_cmd_queue: start: Num_HCI_Command_Packets=1

[1744.623489 <000.049375>] send_cmd_queue:  (11):
0x01 0x09 0x04 0x07 0x61 0x18 0x7b 0x03 0xe0 0x00 0x00 
HCI: send_cmd_queue: end : 0 cmds left in queue

[1744.650052 <000.026563>] hci_receive_data:  (7):
0x04 0x0f 0x04 0x00 0x01 0x09 0x04 
hci_receive_data: hci-7
HCI: hci_receive_data: WAIT_FOR_PACKET_TYPE
HCI: hci_receive_data: WAIT_FOR_EVENT_TYPE
HCI: hci_receive_data: WAIT_FOR_EVENT_LENGTH

[1744.651302 <000.001250>] process_event (4):
0x00 0x01 0x09 0x04 
HCI: release_cmd_timer
HCI: process_event: COMMAND_STATUS
HCI: update_nhcp: Num_HCI_Command_Packets=1
HCI: send_cmd_queue: start: Num_HCI_Command_Packets=1
HCI: send_cmd_queue: end : 0 cmds left in queue

[1744.790052 <000.138750>] hci_receive_data:  (14):
0x04 0x03 0x0b 0x24 0x27 0x00 0x61 0x18 0x7b 0x03 0xe0 0x00 0x01 0x00 
hci_receive_data: hci-14
HCI: hci_receive_data: WAIT_FOR_PACKET_TYPE
HCI: hci_receive_data: WAIT_FOR_EVENT_TYPE
HCI: hci_receive_data: WAIT_FOR_EVENT_LENGTH

[1744.794531 <000.004479>] process_event (11):
0x24 0x27 0x00 0x61 0x18 0x7b 0x03 0xe0 0x00 0x01 0x00 
HCI: process_event: CONNECTION_COMPLETE: LMP PDU Not Allowed
lp_connect_cfm (neg), wake up flag not set
BT SYS: process_event: CONNECTION_COMPLETE LMP PDU Not Allowed
BT SYS: ERROR: reset_hci_con_bd: Didn't find connection with con_hdl 39

Steve
_____________________
RLW Inc.
Office:  518-885-6949
Cell  :  814-883-6325
Fax   :  413-803-8192
-
To unsubscribe from this list: send the line "unsubscribe bluetooth-dev" in
the body of a message to majordomo@xxxxxxx.com