RE: direction for g21-23



Hi!

The data sheet is correct (the direction of g16-g23 can be set).

Regards
/Mikael

-----Original Message-----
From: owner-dev-etrax@xxxxxxx.com]On">mailto:owner-dev-etrax@xxxxxxx.com]On
Behalf Of Anders Blomdell
Sent: Wednesday, January 24, 2001 12:12 PM
To: dev-etrax
Subject: direction for g21-23


According to "ETRAX 100 Data Sheet"@p115 g16-g23 are inout when operating
as General I/O, but according to "Etrax 100 Designer's Reference"@p25 only
g16-g20 can change direction (via the g16_20dir). Which documentation is
correct?

Anders Blomdell


------------------------------------------------------------------------------
 Anders Blomdell
 Department of Automatic Control        Email: anders.blomdell@xxxxxxx.se
 Lund Institute of Technology           Phone: +46 46 222 4625
 Box 118, S-221 00 Lund, Sweden         Fax:   +46 46 138118