RE: execution time



The register itself is fast (one clock cycle to write) but the code
generated to load the values to store in the register may be 
several cycles.

Example 1:
*R_PAR0_CTRL_DATA = 33;
Approx time : 5 cycles

Example 2:
*R_PAR0_CTRL_DATA = variable1 | variable2;
Approx time : 10 cycles

Example 3:
*R_PAR0_CTRL_DATA = var1 % var2
Approx time: 100 cycles

Execution times can be found in the ETRAX 100LX programmer's
reference.

/Mikael 

-----Original Message-----
From: owner-dev-etrax@xxxxxxx.com]On">mailto:owner-dev-etrax@xxxxxxx.com]On
Behalf Of Szabo, Tamas
Sent: Thursday, November 21, 2002 1:15 PM
To: dev-etrax
Subject: execution time


Hi,

Sorry this may sounds like newbie question (and really :-).

How much is the execution time of *R_PAR0_CTRL_DATA = anything | or |
something | else (or other register write)?

Thx

Sza2

Problems with Windows - Reboot.
Problems with Linux       - Be root.




**********************************************************************************************
The information contained in this message or any of its attachments may be confidential and is intended for the exclusive use of the addressee(s). Any disclosure, reproduction, distribution or other dissemination or use of this communication is strictly prohibited without the express permission of the sender. The views expressed in this email are those of the individual and not necessarily those of Sony or Sony affiliated companies. Sony email is for business use only. 